Screw the parallel unit

螺杆并联机组1
  • 螺杆并联机组1
  • 螺杆并联机组2
Screw compressor compared with the characteristics of the parallel unit
1 characteristics of screw compressor
1.1 case: double-body design, in addition to the pressure load, more noise reduction function.
1.2 rotor: can use the latest 5:6 of the asymmetric rotor profile, in conditions of continuous operation, the rotor can maintain optimum clearance values, in order to achieve the highest efficiency requirements.
1.3 suction filter: fitted to the compressor suction mouth, dirty particles and foreign bodies in the system can be filtered to avoid being sucked into the compressor, causing motor with a rotor failure.
1.4 oil filters: casing below the oil filter has a 200 mesh filter, making access to volume adjustment piston, bearings and rotor oil filter clean to prevent filings entering the capacity within a spherical body and bearing, damaged parts.
1.5 drive motors: squirrel-cage motors for high efficiency and stable quality, and high efficiency.
1.6 built-in oil separator: internal structure with three-stage oil filter body, and high density oil filter, make the most of their oil and gas separation, oil separation efficiency of up to 99.7% per cent, external covering design, the compressor operation noise to a minimum.
1.7 capacity regulating institutions and capacity and solenoid valves: four-segmentor no segment can be used to control the compressor capacity control and can be used with a variety of built-in volumetric ratio, used in a variety of different conditions, and to operate at maximum efficiency.
2 characteristics of the parallel unit
2.1 according to the cold start and cold storage number of required cooling capacity, and automatically open the number of compressors, less inventory or chilling requirement changes are different in different seasons may only need a host can driveall refrigerator, which greatly saves energy, generally comparable with saving more than 20% power unit;
2.2 compact: compressor, accumulator, gas-liquid separator, such as including electronic control equipment all together, highly integrated design concept, greatly savesroom area;
2.3 other hosts when a host fails or is not affected for all cold storage and refrigeration, cold storage to minimize the risk of the goods;
2.4 each boot host is automatically selected when the accumulating working time of the shortest first boot, ensuring that all work the same hours of the host, and can bepowered on by fuzzy control individual hosts frequent, will prolong the life of host;
2.5PLC high stability ensures long-term operation of electrical control will not fail;
2.6PLC control can really achieve refrigeration systems do not require professionalmanagement, and enables remote monitoring, one in the main room, you can always monitor the working conditions of any cold storage;
2.7 color touch screen HMI, users simply set the working parameters of cold storageand host.
2.8PLC high stability ensures long-term operation of electrical control will not fail;
2.9 with a phase failure, phase sequence and voltage, oil pressure, liquid level, high voltage, low voltage, motor overload protection system, oil-flow protection, air power protection, such as protection and automatic alarm protection level, involved human intervention when necessary;
2.10PLC controls can really achieve refrigeration systems do not require a professional to manage, can be achieved in the main room, it can monitor the operation of any warehouse or for remote operation of monitor, running conditions, remote faultdiagnosis and processing unit design with high reliability.
2.11 maintenance low, automatic control, ensure the equipment running in peak condition, play equipment for maximum effectiveness.
2.12 quick response. The control system uses a closed-loop control, the temperature can be maintained at a set interval and fuzzy control, automatically adjusted according to the actual speed of startup and shutdown of the compressor, for customersto save more time for production.
2.13PLC shows the basic information units, as follows:
1) compressor suction pressure, temperature, oil temperature, oil pressure difference (oil filter)
2) motor current, voltage
3) percentage of compressor loading and unloading
4) external start/stop order State compressor start condition
5) basic unit automatic protection function
6) over current
7) compressor start failure, compressor running failure total failure sensor failure
Of course, compared with the traditional system of ammonia, fluoride also has its disadvantages of screw compressors in parallel system, for example in terms of initial investment, fluorine parallel screw compressor system is slightly higher than the ammonia system, refrigerant, oil and other costs will be slightly higher.