Refrigeration and four-way valves failed, what should I do?

Release time:2016-10-08 14:42:47
Consists of air conditioner refrigeration system, air system, structural systems, electrical systems. Valve as an important part of the cooling system, its quality will lead directly to the parts of the product quality. To do this, we need to design, manufactureand inspection of each loop should strictly control the quality. Then, four-way valvesthe refrigeration system fails, what can you do? Today, and most bacteria's learningsolution together!
 
A, function
 
Are key components in the heat pump air conditioner, cooling, heating conversion function in the refrigeration system, by replacing the compressor exhaust pipe and the direction of the suction tube into the evaporator and the condenser, so as to achieve cooling and heating purposes.
 
Second, the principle of
 
1 structure
 
By the pilot valve and main valve and solenoid is composed of three parts. Using the pilot valve controls, using differential pressure switch for reversing the main valve.Four-way valve of the four taken over are: "d" nozzle discharge pipe, the "e" port low-pressure valve takes over, "s" compressor suction tube "c" condenser tubes.
 
2 working principle
 
When the solenoid is de-energized, pilot valve left in compression spring-driven, high pressure gas into the capillary tube into the piston Chamber, on the other hand,gas piston cavity due to pressure difference on both ends of the piston, main slide valve and piston to the left, the e, s, takes over the same, d, c, takes over the same. D,c AC compressor high pressure fluids capillary flow into the Bowl cavity on the right,left superior valve Bowl low pressure fluid by the e and s by capillary flow compressors, left, move the block left and right valve Bowl to form a refrigeration cycle.
 
When the solenoid is powered on, pilot operated spool valve solenoid coils generate magnetic forces overcome the tension and compression springs under the actionshifts to the right, high pressure gas into the capillary tube into the piston Chamber,on the other hand, gas piston cavity due to pressure difference on both ends of thepiston, piston and valve right, s, c, took over the same, d and e took over the same.AC compressor high pressure fluid by d, e capillary flow into the cavity left Bowl, Bowl cavity right valve low pressure fluid by capillary flow compressor c, s, and bowls left and right valve and valve block right to form a heating cycle.
 
Third, the key quality control points
 
1, the valve body: internal leak, high pressure, minimum pressure difference, the lowest tripping voltage, reversing flexibility;
 
2, solenoid Coil: temperature, insulation resistance, dielectric strength, insulation between turns of coils.
 
Analysis of common quality problems in four,
 
1, excessive internal leak: mainly with not enough close main slide valve and main valve seat;
 
2, produced in the process of reversing abnormal noise:
 
A, in the four-way valve in the process of reversing, electromagnetic fluid mixed with gas in a liquid state, formation intermittently back pressure piston moving vibration, issued with "goo, and Goo" sound;
 
B, when the Pistons and main slide valve and reversing slow, vulnerable to the effects of fluid, directional sound with vibration;
 
C, when reversing, high pressure, friction, the main slide valve and directional tone and vibration;
 
D, when reversing, nylon main slide valve and the brass slide and different sounds are produced by.
 
3, four-way valve side (gas)
 
A, system causes: basic requirements for four-way valve is a pressure difference between the two ends of the piston must be greater than the friction, or four-way valvewill not reverse, reversing the minimum pressure difference is required by the flow of the system to be guaranteed. About four-way valve piston cavity pressure difference greater than friction, four-way valve began to reverse. When the main slide valvemoves to the middle position, the ESC taken over three of the four-way valve works,compressor discharge from the four-way valve d taken over directly by the EC to take over direction of s-takeover (compressor suction tube) pressure drop at once, forming an instant status. If displacement compressors than the middle of the four-way valve flow, you can build enough directional pressure differential is the four-way valve in place. Instead, such as displacement compressors is smaller than the middleof the four-way valve flow, the four-way valve the minimum action required pressure difference cannot be established, four-way valve cannot continue to reverse and stopped in the middle of the form.
 
B, the body structure: with not enough and sliders with the piston and valve body cavity space, bad lead sealing performance.
 
4, four-way valve jammed not reversing:
 
A,, and system reasons: Dang four pass valve internal irrigation full liquid Shi, compressor started Shi of impact pressure will through liquid moments passed to four pass valve internal all parts, dang main sliding valve in Middle location Shi, main sliding valve will put ESC three article took over part cover live, but has must of clearance, if impact pressure had big and clearance too small, have not to effective of unloading load, the force is greater than screws by can bear of pressure (6MPa) Shi, on will occurred liquid hit damage of phenomenon and caused card died not reversing.
 
B, guide and piston connection strength is not enough, when the system pressure will cause the deformation and not reversing;
 
C, impurities in the system, into the main valve body valve jammed and not reversing;
 
5, electromagnetic coil shorted or open circuit: electromagnetic coil wire insulation.
 
6 problems, the current four-way valve: it is not reversing. Direct effect is to judge its four outlet pipe temperature is the same, if it works then either cooling or heatingits high-pressure hose or low pressure pipe is hot.