Refrigeration equipment to improve the functioning of the thermal environment in the workplace

Release time:2016-10-24 16:01:39
Cooling fan is cooling and blower combination heat exchanger, cooler using a blower to force air through the cooling flow rate and improve heat transfer coefficient, dry air cooling and improve thermal Exchange conditions decrease the temperature,and cold temperature balance on various parts to improve cargo-air heat exchange.Then, cooler way in improving the operation of the thermal environment in the workplace are there? And most bacteria together to get to know about it!
 
Air cooler at work during the evaporator surface should be having a thin cream evenly, without no frost or frost not uniform. In addition, pipe welds or joints, there shall be no leakage of refrigerant.
 
Air coolers for cooling, freezing, cooling, refrigerated cargo use. Cooling refrigerated cargo between the use of wind machines in addition to cool the cold air circulation, but can also introduce outdoor air, cool back into the cold, for cold air.
 
, Cooler operation and management
 
Before starting the cooling fan should rotate blower motor check transmission is good, blades and shield excessive friction, rotation, condition is good. When irregularities are found, should be adjusted to repair, and then enable to ensure cooler operation security.
 
With a duct and outlet valve air system should be based on the size of indoor air flow and air flow, adjust the air valve, so evenly in the interior air circulation.
 
In the operation, dry-type air cooler cooling tube surface, having Frost, if frosting is not good, the reasons should be identified and adjusted. Cool the frosting tube should not be too thick, cream layer is too thick, reduces the space between the tube, impeding air circulation, reduces heat dissipation and heat transfer coefficient of thecooling pipes. Seriously, even the cooler failed. At work should always check the frosting and defrosting work carried out in a timely manner.
 
Both blowers centrifugal and axial-flow, its actions and considerations are basically the same. When do the reverse operation of axial-flow blower, spewing wind changing direction, and the wind pressure and the wind changed;
 
Centrifugal blower will not operate reverse, when the reverse operation not only import and export wind direction, and significant reduces wind pressure and wind. Therefore, after you install and check the blower and motor, check blower operation direction whether it meets the requirements.
 
Second, the blower before starting inspections
 
Check your blower motor bolt is loose.
 
Loose coupling bolts, rubber gasket is complete, when operation, impeller and casing friction, is not overweight and stuck, tight is appropriate.
 
Check if the bearings have sufficient oil.
 
When you start the blower, as the following conditions, you must stop.
 
1, the blower does not turn or spin slower.
 
2, blower and motor sounds abnormal.
 
3, overheating or found burned taste or smoke.
 
4, bearing of blower or motor temperature too high.
 
5, the fuse on the startup disk.
 
6, more than the rated current value.