Fruit display cabinet not cooling how to repair?

Release time:2016-10-27 15:28:22
As long as the machine is bound to failure, including fruit display case is no exception, only usually caring more about it can be better to use, generally fruit display cabinet not cooling due mainly: refrigeration the refrigerants used up or leaking out of the system, refrigerants or refrigeration system for not cleaning the debris caused the fouling not circulate for a long time. I often keep the fruit display cabinet Interior clean.
 
, Fruit display cabinet expansion valve and a valve adjustment, system of refrigerant,air in cooling system, valve plate Assembly seal bad compressor piston-liner wear. How to judge the fresh cabinet not cooling why?
 
II, and with finger back contact compressor export to condensation device pipeline, see whether has obviously temperature rose, if has must temperature rose and evaporator pipeline also knot cream words, is for refrigeration agent insufficient; if pressure and downtime Shi of pressure almost, is proved fruit show cabinet refrigeration compressor valve Board component has problem, compressor lost inhale, and exhaust capacity; if pressure also declined, but drop not to normal, is should view evaporator whether no cream or knot virtual cream, and knot dew. If the pressure drops and the export pipes without heat or hot and then cold, then the proof cooling systemblockage or fouling phenomena.
 
Three, fruit display cabinets are gasification using liquid refrigerant in the refrigeration system in the course of fruit display cabinets in the heat and in the presence of refrigeration compressors, heat to the surrounding environment. Natural convectioncooling through air conditioners to cool the food.
 
Four, in stop State, the spin valve Rod counterclockwise, remove the screws on the process, put them to repair the "silk", fitted with connecting pipe with the pressure gauge, gauge valve closed, Rotary intake valve stem clockwise around a circle, make the intake valve was a three-way, observe the door pressure is normal. If the pressure is normal, open fruit display case refrigeration compressors, pressure is reduced tonormal values.
 
Five, if the fruit display cabinets due to welding or improper use, leaks in the cooling system, fruit display cabinet in the refrigeration system refrigerant must have all missed time. No fruit display cabinet refrigerants, refrigeration could not be achieved.
 
Six fruit display cabinets, and tested the voltage is normal, when the voltage is 220Vcompressor still did not respond, you can replace the start relay and protectors to try. After you replace the start relays and protection, still does not start, there are onlytwo possible: 1. the compressor is damaged because of improper use. 2. the lines: one is in the line of fire and the zero line voltage 220V, one is between the wire and the ground wire of the voltage is 220V.